12 BATTERY REQUIREMENTS
CAUTION: refer to the maker’s technical characteristics (capacity and starting current) of the
battery used.
Example: Exide Maxxima 900, 12 volts, capacity 55 Ah / starting current 800 CCA.
The higher the CCA the more suitable the batteries are, large capacity batteries with a low
CCA may be inferior to much smaller battery’s with a higher CCA .
NOTE :in the case of dedicated batteries charged by alternator, the reference for the charge
must be taken after the diode-splitting block (if in doubt, consult a marine electrician).
Thruster performances are quoted with a minimum 22 Volts at the terminals of a 24 Volts
motor or 11 for 12 volts (thruster running, boat in water).
+
-
+
-
+
-
+
-
Electric Battery isolator
recomended (option)
Fuse
Power Connections
Thruster Power supply
24 V 110 Ah
+
-
+
-
Thruster Power supply
12 V 110 Ah
+
+
-
-
Thruster Power supply
24 V 55 Ah
12v 55 Ah 12v 55 Ah
12v 55 Ah
12v 55 Ah
12v 55 Ah 12v 55 Ah
12v 55 Ah 12v 55 Ah
+
_
L/RL/R
(Negative)
A1
13 POWER CABLE SECTIONS ( BATTERIES TO RELAY )
Measure the total length (the shortest and most direct route possible) of the main power
cables between the batteries and the motor power relay ( + & - in drawing ) .Total length is
the + length added to the - length .
NOTE: when choosing your cable sections do not forget to take into consideration the
ampacity rating of the cables concerned. These cables must be of the highest thermal class
available.
The following chart takes into account only permissible voltage drop, it does not represent
the ampacity rating.
The ampacity rating is specific to each cable manufacturer.
Cable lengths
to and from
Series 60 / 80
12 V
Series 60 / 80
24 V
For 5 m (2,5 x 2) 50 mm² 35 mm²
For 10 m (5 x 2) 70 mm² 50 mm²
For 15 m (7,5 x 2) 95 mm² 70 mm²
For 20 m (10 x 2) 120 mm² 95 mm²